The Indian Journal of Chest Diseases and Allied Sciences

Register      Login

VOLUME 58 , ISSUE 4 ( October-December, 2016 ) > List of Articles

EDITORIAL

Sleep Study: PSG versus WatchPAT

S.N. Gaur, Kuldeep Patial

Citation Information : Gaur S, Patial K. Sleep Study: PSG versus WatchPAT. Indian J Chest Dis Allied Sci 2016; 58 (4):217-219.

DOI: 10.5005/ijcdas-58-4-217

License: CC BY-NC 4.0

Published Online: 18-11-2022

Copyright Statement:  Copyright © 2016; The Author(s).


Abstract

PDF Share
  1. Watch-PAT™200 Unified Operation Manual. Itamar Medical Ref # OM2196331. Available at URL: http://www.itamarmedical. com/wp-content/uploads/2016/07/WP200-unifiedoperation-manual.pdf
  2. Hedner J, White DP, Malhotra A, Herscovici S, Pittman SD, Zou D, et al. Sleep staging based on autonomic signals: a multi-center validation study. J Clin Sleep Med 2011;7:301–6.
  3. Breseler M, Sheffy K, Pillar G, Preiszler M, Herscovici S. Differentiating between light and deep sleep stages using an ambulatory device based on peripheral arterial tonometry. Physiol Meas 2008;29:571–84.
  4. Herscovici S, Pe'er A, Papyan S, Lavie P. Detecting REM sleep from the finger: automatic REM sleep algorithm based on peripheral arterial tone (PAT) and actigraphy. Physiol Meas 2007;28:129–40.
  5. Yalamanchali S, Farajian V, Hamilton C, Pott TR, Samuelson CG, Friedman M. Diagnosis of obstructive sleep apnea by peripheral arterial tonometry meta-analysis. JAMA Otolaryngol Head Neck Surg 2013;139:1343–50.
  6. Camilon PR, Camilon MP, Nguyen SA, Gillespie MB. WatchPAT™ versus polysomnography: a meta-analysis. American Academy of Otolaryngology - Head and Neck Surgery Annual Meeting: Orlando; 2014.
  7. Townsend D, Sharma A, Brauer E, Scattarelli D, McEiver J, Eiken T, et al. Assessing efficacy, outcomes and cost savings for patients with obstructive sleep apnea using two diagnostic and treatment strategies. Sleep Diag Ther 2007;7:1–8.
  8. Berry RB, Hill G, Thompson L, McLaurin V, Randall M. Portable monitoring and auto-titration versus polysomnography for the diagnosis and treatment of sleep apnea. Sleep 2008;31:1423–31.
  9. Choi JH, Kim EJ, Kim YS, Choi J, Kim TH, Kwon SY, et al. Validation study of portable device for the diagnosis of obstructive sleep apnea according to the new AASM scoring criteria: Watch-PAT 100. Acta Otolaryngol 2010;130:838–43.
  10. Pang KP, Gourin CG, Terris DJ. A comparison of polysomnography and the WatchPAT in the diagnosis of obstructive sleep apnea. Otolaryngol Head Neck Surg 2007;137:665–8.
  11. Pittman SD, Pillar G, Berry RB, Malhotra A, MacDonald MM, White DP. Follow-up assessment of CPAP efficacy in patients with obstructive sleep apnea using an ambulatory device based on peripheral arterial tonometry. Sleep Breath 2006;10:123–31.
  12. Zou D, Grote L, Peker Y, Lindblad U, Hedner J. Validation a portable monitoring device for sleep apnea diagnosis in a population based cohort using synchronized home polysomnography. Sleep 2006;29:367–74.
  13. Weimin L, Rongguang W, Dongyan H, Xiaoli L, Wei J, Shiming Y. Assessment of a portable monitoring device WatchPAT-200 in the diagnosis of obstructive sleep apnea. Eur Arch Otorhinolaryngol 2013;270:3099–105.
  14. Levendowski DJ, Zack N, Rao S, Wong K, Gendreau M, KranzlerJ, et al. Assessment of the test- retest reliability of laboratory polysomnography. Sleep Breath 2009:13:163–67.
  15. Aarab G, Lobbezoo F, Hamburger HL, Naeije M. Variability in the apnea-hypopnea index and its consequences for diagnosis and therapy evaluation. Respiration 2009;77:32–7.
  16. Onder NS, Akpinar ME, Yigit O, Gor AP. Watch peripheral arterial tonometry in the diagnosis of obstructive sleep apnea: influence of aging. Laryngoscope 2012;122:1409–14.
  17. Ceylan T, Firat H, Kuran G, Ardic S, Bilgin E, Celenk F. Quick diagnosis in obstructive sleep apnea syndrome: WatchPAT-200. Iran Red Crescent Med J 2012;14: 475–8.
  18. O'Brien LM, Bullough AS, Shelgikar AV, Chames MC, Armitage R, Chervin RD. Validation of WatchPAT-200 against polysomnography during pregnancy. J Clin Sleep Med 2012;8:287–94.
  19. Yuceege M, Firat H, DemirA, Ardic S. Reliability of the WatchPAT-200 in detecting sleep apnea in highway bus drivers. J Clin Sleep Med 2013;9:339–44.
  20. Hedner J, Pillar G, Pittman SD, Zou D, Grote L, White DP, et al. A novel adaptive wrist actigraphy algorithm for sleepwake assessment in sleep apnea patients. Sleep 2004;27:1560–66.
  21. Zhang J, Wang CY, Wang NY, Liu JQ, Du JY, Zhou GX, et al. Evaluation of a portable device based on peripheral arterial tone in the detection of obstructive sleep apnea. Chinese J Otorhinolaryngol Head Neck Surg 2012;47:112–16.
  22. Kang D, Ye JY, Zheng L, Zhang JB, Bian QL. Evaluation of WatchPAT as a diagnosing test for patients with obstructive sleep apnea hypopnea syndrome. Chinese J Otorhinolaryngol Head Neck Surg 2012;47:813–6.
PDF Share
PDF Share

© Jaypee Brothers Medical Publishers (P) LTD.